Products

YAWATA 309L-16
(For 22%Cr-12%Ni Stainless steel & Dissimilar Metals)

Classification : AWS A 5.4 : E309L-16,  JIS Z 3211 : ES309L-16,  DIN 8556 : E 23 12 L 26

Approvals : ABS, TIS

Applications : Welding of mild steel sheet, pipes and light guages for drums and structures. 

PDFYawata-Pamphlet-Stainless.pdf

 

Property

YAWATA 309L-16 is a lime-titania type stainless steel electrode. Low carbon 22%Cr-12% Ni deposited metal shows extremely high crack resistance due to its high ferrite content. 

Classification

AWS A 5.4 : E309L-16
JIS Z 3211 : ES309L-16
DIN 8556 : E 23 12 L 26

Chemical Composition
 
C
Si
Mn
P
S
Cr
Ni
Mo
Cu
Req.    
≤0.04
≤1.00
0.5-2.5
≤0.040
≤0.030
22.0-25.0
12.0-14.0
≤0.75
≤0.75
Typ.    
0.03
0.85
1.3
0.029
0.031
24.0
12.4
0.12
0.11
Req. = Requirement
Typ. = Typical results
N.S. = Not Specified
C.L. = Combined Limit for Mn + Ni + Cr + Mo + V
Mechanical Properties
  Tensile Strength
N/mm2 (kgf/mm2)
Elongation 
%
Req.      ≥450 (46) ≥28
Typ.      450 (46) 28
Recommended Size and Power Range
Diameter/Length (mm) 2.0/300 2.6/350 3.2/350 4.0/350 5.0/350
Welding Position Current (A)
F 40-50 50-70 80-100 110-140 140-170
V, OH 35-45 45-60 70-90 100-130 -

< AC , DC+ >
Recommendations for Use
1. Use dry electrodes only. Damp electrodes should be re-dried at 200~250 ℃ for 60 minutes before use.
2. Dirt such as oil, grease and dust should be completely removed from groove.
3. Excessively wide weaving may cause welding defects. Keep weaving width to less than 2.5 times electrode diameter